Explain about your water sampling?

screenshot 2026 06 22 115801


๐๐ซ๐ž๐ฉ๐š๐ซ๐ž
Before collecting samples, identify outlets to sample, type of testing.
sampling bin contain schedule, nose mask, sterile bottles, non sterile bottle, TOC
bottle, heat resistant gloves, extra bottle and stopwatch.

๐’๐š๐Ÿ๐ž๐ญ๐ฒ
Protect yourself and There is no contamination from our end for water.
Wear personal protective equipment (PPE) such as gloves, safety glasses, and a nose
mask.

๐’๐š๐ง๐ข๐ญ๐ข๐ณ๐ž
Sanitize your hands with 70% IPA.

๐ƒ๐ซ๐š๐ข๐ง
Open the sampling valve and let water drain for 1โ€“2 minutes or 20โ€“30 seconds.
GMP area, no need to drain water.

๐‘๐ข๐ง๐ฌ๐ž
Rinse the bottle with the water to be tested only for chemical analysis.
No rinse required for microbiology analysis because glass bottles already sterile.

๐‚๐จ๐ฅ๐ฅ๐ž๐œ๐ญ
Depending on the type of analysis, collect the sample in a sterile glass bottle or
normal glass bottle.
Sterile for microbiology
Non sterile for chemical
๐‚๐ก๐ž๐ฆ๐ข๐œ๐š๐ฅ ๐€๐ง๐š๐ฅ๐ฒ๐ฌ๐ข๐ฌ
Collect the sample in a glass bottle for chemical after microbiology analysis, then
TOC sampling.

๐“๐Ž๐‚ ๐€๐ง๐š๐ฅ๐ฒ๐ฌ๐ข๐ฌ
Collect about 100 ml of sample in a glass bottle with minimal head space and
wrapped with parafilm before sampling TOC bottles should be cleaned with HCL and
stored for drying.

๐๐จ๐ญ๐ž: Dedicated only for TOC sample bottle, should mark the bottle.

๐Œ๐ข๐œ๐ซ๐จ๐›๐ข๐จ๐ฅ๐จ๐ ๐ข๐œ๐š๐ฅ ๐€๐ง๐š๐ฅ๐ฒ๐ฌ๐ข๐ฌ
Collect about 250 ml of sample in a sterile glass bottle.
No need to Rinse the bottle.
Do not touch the bottle to the water loop.
Closing the cap as soon as possible.
If it is not possible to collect water samples, use a sterile hose pipe.
For treated water use STS bottle
STS – sodium thiosulphate

๐‹๐š๐›๐ž๐ฅ
Label the container with the sample identity, sampling point, date and time of
sampling, and what the sample is being tested for like Borewell water, treated water,
RO water and purified water.
After reaching the lab genrate AR number for each water sample using LIMS or
manual writing log books.
๐’๐ญ๐จ๐ซ๐ž
If you are not taking a water sample for microbiology analysis, keep the sample at 2
8ยฐC.