The limit of Total Organic Carbon (TOC) in pharmaceutical water systems, such as Purified Water (PW) and Water for Injection (WFI), is typically set at 500 ppb (parts per billion).
This limit is specified in pharmacopeias like the USP (United States Pharmacopeia) and EP (European Pharmacopeia) to ensure water purity by controlling organic contamination levels.
Total Organic Carbon (TOC) is a measure of the total amount of carbon in organic
compounds present in water.
Set alert and action limits for control failure of TOC results.
Based on yearly trend set alert and action limits.
๐๐ฅ๐๐ซ๐ญ ๐ฅ๐ข๐ฆ๐ข๐ญ
The alert limit is a threshold that indicates a potential deviation but is not an immediate failure. It acts as an early warning signal that the TOC .
The alert limit is 100 ppb
๐๐๐ญ๐ข๐จ๐ง ๐ฅ๐ข๐ฆ๐ข๐ญ
The action limit is the point at which a formal investigation or corrective action is required. It indicates a potential or actual failure to meet water quality standards.
The action limit is 250 ppb
๐๐๐ซ๐ฆ๐ข๐ฌ๐ฌ๐ข๐๐ฅ๐ ๐ฅ๐ข๐ฆ๐ข๐ญ
This is the maximum allowable TOC level to ensure water purity, established by regulatory
bodies like USP and EP.
The permissible limit is 500 ppb